Ascr AAAC 12kv/24kv/38kv overhead line silicone rubber insulation sleeve

 ITEM 1  : INSULATION COVER FOR 70 MM2  - 15 KVITEMSPECIFICATIONSUNITREQUIREDGUARANTEED1GENERAL DATA   1.1MANUFACTURER INDICATEHEMG COUNTRY INDICATEChina1.2MATERIAL OF INSULATION COVER SILICON RUBBERSILICONE RUBBER1.3MODEL OR CATALOGUE NUMBER INDICATEWSKG1.4CERTIFICATE ISO 9

Featured Products

12kv/24kv/38kv Silicon Rubber Insulating Cover of Ascr AAAC for Over Head Line
12kv/24kv/38kv Silicon Rubber Insulating Cover of Ascr AAAC for Over Head Line
12kv/24kv/38kv Silicon Rubber Insulating Cover of Ascr AAAC for Over Head Line
12kv/24kv/38kv Silicon Rubber Insulating Cover of Ascr AAAC for Over Head Line
12kv/24kv/38kv Silicon Rubber Insulating Cover of Ascr AAAC for Over Head Line12kv/24kv/38kv Silicon Rubber Insulating Cover of Ascr AAAC for Over Head Line
 ITEM 1  : INSULATION COVER FOR 70 MM2  - 15 KV
ITEMSPECIFICATIONSUNITREQUIREDGUARANTEED
1GENERAL DATA   
1.1MANUFACTURER INDICATEHEMG
 COUNTRY INDICATEChina
1.2MATERIAL OF INSULATION COVER SILICON RUBBERSILICONE RUBBER
1.3MODEL OR CATALOGUE NUMBER INDICATEWSKG
1.4CERTIFICATE ISO 9001 AND ISO 14001 YESYES
1.5STANDARDS OF MANUFACTURE AND TESTS ACCORDING POINT 2 
2CONDITIONS OF OPERATION IN CONTINUOUS REGIME OF THE INSULATING COVERS.   
2.1MAXIMUM VOLTAGE.KV1515
2.3NOMINAL VOLTAGES OF THE NETWORK.KV10, 13.2, 13.810, 13.2, 13.8
2.4FREQUENCYHZ6060
2.5CALIBER OF CABLES WHERE THEY WILL BE INSTALLED. UNTIL 70 MM2UNTIL 70 MM2
2.6MATERIAL OF THE CABLES WHERE THEY WILL BE INSTALLED. CU AND AAACCU AND AL
3ELECTRICAL PROPERTIES OF THE COVER MATERIAL (1).   
3.1DIELECTRIC STRENGTH.KV/CM175 OR MORE≥175
3.2VOLUMETRIC RESISTIVITY.OHM/CM1X10  13 OR MORE1X10  14
3.3CONSTANT DIELECTRIC. 5 OR LESS2-3
4VOLTAGES OF PROOF OF THE COVER (1).   
4.1A NOMINAL FREQUENCY IN DRY 1 MINUTE.KV1515
4.2A INDUSTRIAL FREQUENCY IN WET 1 MINUTE.KV1515
5PROPERTIES OF THE MATERIAL OF THE INSULATING COVER (1).   
5.1BREAKING STRAIN.Mpa4.8 OR MORE4
5.2ELONGATION OF BREAK.%200 OR MORE≥200
5.3RANGE OF OPERATING TEMPERATURE.°CFROM -10 TO +100from -10C to +100C
5.4WATER ABSORPTION.%1 OR LESS1 or less
5.5RESISTANCE TO UV RAYS. YESyes
5.6RESISTANT TO TRACKING YESyes
5.7RESSITANTE TO THE MOZONO. YESyes
5.8RESISTANT TO URIC ACID AND FATS. YESyes
5.9RESISTANT TO THE RIPPED. YESyes
6DIMENSIONS AND DESIGN OF THE COVERS (2).   
6.1COVER DESIGN INDICATE ADN SCHEME 
6.2THICKNESS.mmINDICATE.≥2.3
6.3INSIDE DIAMETER.mm INDICATE12
6.4CABLE CALIBERS TO COVER.mm2INDICATE70
6.5LABELED. BRAND AND MODELNo
7INSTALLATION OF COVER WITH ENERGIZED LINE AND ITS ACCESSORIES (3).   
7.1EASY TO INSTALL. YES , INCLUDE GUIDEYES , INCLUDE GUIDE
Pay attention to the personal safety with energized line
7.2INCLUDE RETAIN ACCESSORIES FOR FIXING THE CABLES AND AVOIDING SLIDES AFTER INSTALLATION. YES, TWO UNITS FOR EVERY 10 MTS OF COVER.CABLE TIE
7.3INCLUDE TOOLS FOR INSTALLATION AND CLOSURE OF THE COVER THAT GUARANTEE THAT DURING ITS OPERATION IS SLIDING ON THE CABLE AND PERIMETER ITS MOUNTING FROM A FIXED POINT OF THE INSTALLER WITH THE SPECIFIED TOOL. YES, 5 EQUIPMENTS FOR MOUNTING YES
7.4REUSABLE. YESYES, IF REQUIRED, WITHOUT GLUE
8PACKING REQUIREMENTS.   
8.1METERS OF COVER BY ROLL.MTSINDICATE100
8.2WEIGHT OF EACH ROLL.KGINDICATE10
8.3PACKAGING RESISTANT TO BLOWS AND FALL OF ACIDS. INDICATEYES
9PRESENT SAMPLE  OF THE COVER AND FIXING ACCESSORIES. YES, COVER AND ACCESORIE FOR MOUNTING.YES
     
 NOTE   :    
 THE PROPERTIES OF THE INSULATING COVERS ARE REFERRED TO THE MANUFACTURING STANDARDS INDICATED IN THE NUMBER 2 attached.
 IT MUST INCLUDE ROOF DESIGN DESIGNS INDICATING ALL DIMENSIONS, PLANS OF ACCESSORIES, FLATS OF FIXING ELEMENTS AND CLOSURE OF INSULATING COVERS.
 THE FOLLOWING TECHNICAL DOCUMENTATION MUST BE INCLUDED.
 Installation manuals, information on the technical characteristics of the fixing accessories, closure of the insulating covers and manuals for the use of the tools.
     
 ITEM 2  : INSULATION COVER FOR 70 MM2  - 25 KV   
ITEMSPECIFICATIONSUNITREQUIREDGUARANTEED
1GENERAL DATA   
1.1MANUFACTURER INDICATEHEMG
 COUNTRY INDICATEChina
1.2MATERIAL OF INSULATION COVER SILICON RUBBERSILICONE RUBBER
1.3MODEL OR CATALOGUE NUMBER INDICATEWSKG
1.4CERTIFICATE ISO 9001 AND ISO 14001 YESYES
1.5STANDARDS OF MANUFACTURE AND TESTS ACCORDING POINT 2 
2CONDITIONS OF OPERATION IN CONTINUOUS REGIME OF THE INSULATING COVERS.   
2.1MAXIMUM VOLTAGE.KV2525
2.3NOMINAL VOLTAGES OF THE NETWORK.KV22.922.9
2.4FREQUENCYHZ6060
2.5CALIBER OF CABLES WHERE THEY WILL BE INSTALLED. UNTIL 70 MM2UNTIL 70 MM2
2.6MATERIAL OF THE CABLES WHERE THEY WILL BE INSTALLED. CU AND AAACCU AND AL
3ELECTRICAL PROPERTIES OF THE COVER MATERIAL (1).   
3.1DIELECTRIC STRENGTH.KV/CM175 OR MORE≥175
3.2VOLUMETRIC RESISTIVITY.OHM/CM1X10  13 OR MORE1X10  14
3.3CONSTANT DIELECTRIC. 5 OR LESS2-3
4VOLTAGES OF PROOF OF THE COVER (1).   
4.1A NOMINAL FREQUENCY IN DRY 1 MINUTE.KV2525
4.2A INDUSTRIAL FREQUENCY IN WET 1 MINUTE.KV2525
5PROPERTIES OF THE MATERIAL OF THE INSULATING COVER (1).   
5.1BREAKING STRAIN.Mpa4.8 OR MORE4
5.2ELONGATION OF BREAK.%200 OR MORE≥200
5.3RANGE OF OPERATING TEMPERATURE.°CFROM -10 TO +100from -10C to +100C
5.4WATER ABSORPTION.%1 OR LESS1 or less
5.5RESISTANCE TO UV RAYS. YESyes
5.6RESISTANT TO TRACKING YESyes
5.7RESSITANTE TO THE MOZONO. YESyes
5.8RESISTANT TO URIC ACID AND FATS. YESyes
5.9RESISTANT TO THE RIPPED. YESyes
6DIMENSIONS AND DESIGN OF THE COVERS (2).   
6.1COVER DESIGN INDICATE ADN SCHEME 
6.2THICKNESS.mmINDICATE.≥3
6.3INSIDE DIAMETER.mm INDICATE12
6.4CABLE CALIBERS TO COVER.mm2INDICATE70
6.5LABELED. BRAND AND MODELNo
7INSTALLATION OF COVER WITH ENERGIZED LINE AND ITS ACCESSORIES (3).   
7.1EASY TO INSTALL. YES , INCLUDE GUIDEYES , INCLUDE GUIDE
Pay attention to the personal safety with energized line
7.2INCLUDE RETAIN ACCESSORIES FOR FIXING THE CABLES AND AVOIDING SLIDES AFTER INSTALLATION. YES, TWO UNITS FOR EVERY 10 MTS OF COVER.CABLE TIE
7.3INCLUDE TOOLS FOR INSTALLATION AND CLOSURE OF THE COVER THAT GUARANTEE THAT DURING ITS OPERATION IS SLIDING ON THE CABLE AND PERIMETER ITS MOUNTING FROM A FIXED POINT OF THE INSTALLER WITH THE SPECIFIED TOOL. YES, 5 EQUIPMENTS FOR MOUNTINGYES,
7.4REUSABLE. YESYES, IF REQUIRED, WITHOUT GLUE
8PACKING REQUIREMENTS.   
8.1METERS OF COVER BY ROLL.MTSINDICATE100
8.2WEIGHT OF EACH ROLL.KGINDICATE10
8.3PACKAGING RESISTANT TO BLOWS AND FALL OF ACIDS. INDICATEYES
9PRESENT SAMPLE  OF THE COVER AND FIXING ACCESSORIES. YES, COVER AND ACCESORIE FOR MOUNTING.YES
     
 NOTE   :    
 THE PROPERTIES OF THE INSULATING COVERS ARE REFERRED TO THE MANUFACTURING STANDARDS INDICATED IN THE NUMBER 2 attached.
 IT MUST INCLUDE ROOF DESIGN DESIGNS INDICATING ALL DIMENSIONS, PLANS OF ACCESSORIES, FLATS OF FIXING ELEMENTS AND CLOSURE OF INSULATING COVERS.
 THE FOLLOWING TECHNICAL DOCUMENTATION MUST BE INCLUDED.
 Installation manuals, information on the technical characteristics of the fixing accessories, closure of the insulating covers and manuals for the use of the tools.
     
     
 ITEM 3  : INSULATION COVER FOR 120 MM2  - 15 KV   
ITEMSPECIFICATIONSUNITREQUIREDGUARANTEED
1GENERAL DATA   
1.1MANUFACTURER INDICATEHEMG
 COUNTRY INDICATEChina
1.2MATERIAL OF INSULATION COVER SILICON RUBBERSILICONE RUBBER
1.3MODEL OR CATALOGUE NUMBER INDICATEWSKG
1.4CERTIFICATE ISO 9001 AND ISO 14001 YESYES
1.5STANDARDS OF MANUFACTURE AND TESTS ACCORDING POINT 2YES
2CONDITIONS OF OPERATION IN CONTINUOUS REGIME OF THE INSULATING COVERS.   
2.1MAXIMUM VOLTAGE.KV1515
2.3NOMINAL VOLTAGES OF THE NETWORK.KV10, 132, 13.810, 13.2, 13.8
2.4FREQUENCYHZ6060
2.5CALIBER OF CABLES WHERE THEY WILL BE INSTALLED. UNTIL  120 MM2UNTIL 120 MM2
2.6MATERIAL OF THE CABLES WHERE THEY WILL BE INSTALLED. CU AND AAACCU AND AL
3ELECTRICAL PROPERTIES OF THE COVER MATERIAL (1).   
3.1DIELECTRIC STRENGTH.KV/CM175 OR MORE≥175
3.2VOLUMETRIC RESISTIVITY.OHM/CM1X10  13 OR MORE1X10  14
3.3CONSTANT DIELECTRIC. 5 OR LESS2-3
4VOLTAGES OF PROOF OF THE COVER (1).   
4.1A NOMINAL FREQUENCY IN DRY 1 MINUTE.KV1515
4.2A INDUSTRIAL FREQUENCY IN WET 1 MINUTE.KV1515
5PROPERTIES OF THE MATERIAL OF THE INSULATING COVER (1).   
5.1BREAKING STRAIN.Mpa4.8 OR MORE4
5.2ELONGATION OF BREAK.%200 OR MORE≥200
5.3RANGE OF OPERATING TEMPERATURE.°CFROM -10 TO +100from -10C to +100C
5.4WATER ABSORPTION.%1 OR LESS1 or less
5.5RESISTANCE TO UV RAYS. YESyes
5.6RESISTANT TO TRACKING YESyes
5.7RESSITANTE TO THE MOZONO. YESyes
5.8RESISTANT TO URIC ACID AND FATS. YESyes
5.9RESISTANT TO THE RIPPED. YESyes
6DIMENSIONS AND DESIGN OF THE COVERS (2).   
6.1COVER DESIGN INDICATE ADN SCHEME 
6.2THICKNESS.mmINDICATE.≥2.3
6.3INSIDE DIAMETER.mm INDICATE15.6
6.4CABLE CALIBERS TO COVER.mm2INDICATE120
6.5LABELED. BRAND AND MODELNo
7INSTALLATION OF COVER WITH ENERGIZED LINE AND ITS ACCESSORIES (3).   
7.1EASY TO INSTALL. YES , INCLUDE GUIDEYES , INCLUDE GUIDE
Pay attention to the personal safety with energized line
7.2INCLUDE RETAIN ACCESSORIES FOR FIXING THE CABLES AND AVOIDING SLIDES AFTER INSTALLATION. YES, TWO UNITS FOR EVERY 10 MTS OF COVER.CABLE TIE
7.3INCLUDE TOOLS FOR INSTALLATION AND CLOSURE OF THE COVER THAT GUARANTEE THAT DURING ITS OPERATION IS SLIDING ON THE CABLE AND PERIMETER ITS MOUNTING FROM A FIXED POINT OF THE INSTALLER WITH THE SPECIFIED TOOL. YES, 5 EQUIPMENTS FOR MOUNTINGYES
7.4REUSABLE. YESYES, IF REQUIRED, WITHOUT GLUE
8PACKING REQUIREMENTS.   
8.1METERS OF COVER BY ROLL.MTSINDICATE100
8.2WEIGHT OF EACH ROLL.KGINDICATE10
8.3PACKAGING RESISTANT TO BLOWS AND FALL OF ACIDS. INDICATEYES
9PRESENT SAMPLE  OF THE COVER AND FIXING ACCESSORIES. YES, COVER AND ACCESORIE FOR MOUNTING.YES
     
 NOTE   :    
 THE PROPERTIES OF THE INSULATING COVERS ARE REFERRED TO THE MANUFACTURING STANDARDS INDICATED IN THE NUMBER 2 attached.
 IT MUST INCLUDE ROOF DESIGN DESIGNS INDICATING ALL DIMENSIONS, PLANS OF ACCESSORIES, FLATS OF FIXING ELEMENTS AND CLOSURE OF INSULATING COVERS.
 THE FOLLOWING TECHNICAL DOCUMENTATION MUST BE INCLUDED.
 Installation manuals, information on the technical characteristics of the fixing accessories, closure of the insulating covers and manuals for the use of the tools.
     
     
 ITEM 4  : INSULATION COVER FOR 120 MM2  - 25 KV   
ITEMSPECIFICATIONSUNITREQUIREDGUARANTEED
1GENERAL DATA   
1.1MANUFACTURER INDICATEHEMG
 COUNTRY INDICATEChina
1.2MATERIAL OF INSULATION COVER SILICON RUBBERSILICONE RUBBER
1.3MODEL OR CATALOGUE NUMBER INDICATEWSKG
1.4CERTIFICATE ISO 9001 AND ISO 14001 YESYES
1.5STANDARDS OF MANUFACTURE AND TESTS ACCORDING POINT 2 
2CONDITIONS OF OPERATION IN CONTINUOUS REGIME OF THE INSULATING COVERS.   
2.1MAXIMUM VOLTAGE.KV2525
2.3NOMINAL VOLTAGES OF THE NETWORK.KV22.922.9
2.4FREQUENCYHZ6060
2.5CALIBER OF CABLES WHERE THEY WILL BE INSTALLED. UNTIL  120 MM2UNTIL 120 MM2
2.6MATERIAL OF THE CABLES WHERE THEY WILL BE INSTALLED. CU AND AAACCU AND AL
3ELECTRICAL PROPERTIES OF THE COVER MATERIAL (1).   
3.1DIELECTRIC STRENGTH.KV/CM175 OR MORE≥175
3.2VOLUMETRIC RESISTIVITY.OHM/CM1X10  13 OR MORE1X10  14
3.3CONSTANT DIELECTRIC. 5 OR LESS2-3
4VOLTAGES OF PROOF OF THE COVER (1).   
4.1A NOMINAL FREQUENCY IN DRY 1 MINUTE.KV1515
4.2A INDUSTRIAL FREQUENCY IN WET 1 MINUTE.KV1515
5PROPERTIES OF THE MATERIAL OF THE INSULATING COVER (1).   
5.1BREAKING STRAIN.Mpa4.8 OR MORE4
5.2ELONGATION OF BREAK.%200 OR MORE≥200
5.3RANGE OF OPERATING TEMPERATURE.°CFROM -10 TO +100from -10C to +100C
5.4WATER ABSORPTION.%1 OR LESS1 or less
5.5RESISTANCE TO UV RAYS. YESyes
5.6RESISTANT TO TRACKING YESyes
5.7RESSITANTE TO THE MOZONO. YESyes
5.8RESISTANT TO URIC ACID AND FATS. YESyes
5.9RESISTANT TO THE RIPPED. YESyes
6DIMENSIONS AND DESIGN OF THE COVERS (2).   
6.1COVER DESIGN INDICATE ADN SCHEME 
6.2THICKNESS.mmINDICATE.≥3
6.3INSIDE DIAMETER.mm INDICATE15.6
6.4CABLE CALIBERS TO COVER.mm2INDICATE120
6.5LABELED. BRAND AND MODELNo
7INSTALLATION OF COVER WITH ENERGIZED LINE AND ITS ACCESSORIES (3).   
7.1EASY TO INSTALL. YES , INCLUDE GUIDEYES , INCLUDE GUIDE
Pay attention to the personal safety with energized line
7.2INCLUDE RETAIN ACCESSORIES FOR FIXING THE CABLES AND AVOIDING SLIDES AFTER INSTALLATION. YES, TWO UNITS FOR EVERY 10 MTS OF COVER.CABLE TIE
7.3INCLUDE TOOLS FOR INSTALLATION AND CLOSURE OF THE COVER THAT GUARANTEE THAT DURING ITS OPERATION IS SLIDING ON THE CABLE AND PERIMETER ITS MOUNTING FROM A FIXED POINT OF THE INSTALLER WITH THE SPECIFIED TOOL. YES, 5 EQUIPMENTS FOR MOUNTINGYES
7.4REUSABLE. YESYES, IF REQUIRED, WITHOUT GLUE
8PACKING REQUIREMENTS.   
8.1METERS OF COVER BY ROLL.MTSINDICATE100
8.2WEIGHT OF EACH ROLL.KGINDICATE10
8.3PACKAGING RESISTANT TO BLOWS AND FALL OF ACIDS. INDICATEYES
9PRESENT SAMPLE  OF THE COVER AND FIXING ACCESSORIES. YES, COVER AND ACCESORIE FOR MOUNTING.YES
     
 NOTE   :    
 THE PROPERTIES OF THE INSULATING COVERS ARE REFERRED TO THE MANUFACTURING STANDARDS INDICATED IN THE NUMBER 2 attached.
 IT MUST INCLUDE ROOF DESIGN DESIGNS INDICATING ALL DIMENSIONS, PLANS OF ACCESSORIES, FLATS OF FIXING ELEMENTS AND CLOSURE OF INSULATING COVERS.
 THE FOLLOWING TECHNICAL DOCUMENTATION MUST BE INCLUDED.
 Installation manuals, information on the technical characteristics of the fixing accessories, closure of the insulating covers and manuals for the use of the tools.

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours